MetorialDocs

Fix SSO and SCIM setup errors in Metorial

For admins: what Metorial SSO errors such as This email domain is not configured and Authentication Error mean, why SCIM requests fail, and how to fix them.

Find the error page or SCIM error below. Each has its fix in Enterprise Admin or in your identity provider. If you are not an admin, send the page's full text to yours.

What you'll learn

  • What each Metorial SSO error page means
  • Why a domain cannot be used for SSO
  • How to read a failed SCIM request

Before you start

Domain errors

This email domain is not configured

The page names the email your identity provider signed the person in as. The identity provider accepted the person, and Metorial refused the email's domain.

  1. Open Enterprise Admin, then Security, Authentication.
  2. Under SSO Domains, select Add Domain and enter the domain shown on the error page.
  3. Add the DNS TXT record Metorial shows, and wait until the domain reads Verified.
  4. Ask the person to sign in again.

If the page says the email "is not a valid email address", the identity provider sent a value without a domain. Map the email attribute to the person's real address in the identity provider.

You need to verify a domain before you can use SSO.

Authentication shows this until one domain reads Verified. Email Verified is not enough, because SAML needs DNS verification. Add the TXT record under DNS verification steps to your DNS settings, with the Record Name and Record Value shown there. Metorial checks for the record periodically.

This domain is currently unverified and cannot be used for SSO until DNS verification succeeds again. means a verified domain lost its TXT record. Add the same record again.

Sign-in errors

Metorial could not authenticate you.

Shown under the title Authentication Error. Metorial could not accept the SAML response. A detail line can follow.

  1. Compare the Entity ID and Reply URL (ACS URL) in the identity provider with the values on the Metorial connection. They have to match exactly, with no trailing slash.
  2. Check that the response and the assertion are signed.
  3. If the signing certificate was rotated, update the connection's metadata in Metorial.
  4. Open the connection and select Test SSO.

The same page can carry one of these messages instead:

MessageCause and fix
Metorial could not verify your SAML response.No active SAML connection matched the response. Check that the connection is active and that the identity provider's app uses this connection's Reply URL
Invalid IdP-initiated SAML response.A sign-in started from the identity provider's app tile arrived without the values Metorial needs. Copy the Reply URL from the connection into the identity provider again
SSO connection is not available.The connection is disabled, deleted, or not completed. Finish or re-enable it under SSO Connections
Provider did not return a redirect URL.The response did not lead back to Metorial. Check the Reply URL and select Test SSO

An error occurred during authentication.

Shown under the title Unable to Authenticate, with a detail line that names the cause:

DetailCause and fix
No connections found for tenant.The organization has no SSO connection. Add one under SSO Connections
Connection not found or disabled for auth.The connection was disabled or removed during the sign-in. Enable it and retry
Account is not active.The Metorial enterprise account is not active. Contact Metorial support
A line that starts with Authorization failed:The identity provider refused the request. The rest of the line is its error

You do not have access to this application

The person authenticated, and the account is not allowed into Metorial. Check the person's entry on the connection's Users tab in Enterprise Admin. If it looks right, contact Metorial support with the email address and the time.

If people sign in and land on a No access page instead, SSO worked and the portal does not admit their SSO group. Open the portal's Settings, then SSO. Set the connection to Everyone has access, or choose Selected SSO groups and add the group.

Setup errors

MessageCause and fix
Could not create SAML connection:Metorial could not read the metadata. The text after the colon names the problem. Paste the complete metadata XML, or use a metadata URL that answers without a sign-in
Could not create SCIM directory:The directory could not be created. The text after the colon names the problem. Check that the connection is enabled, then add the directory again
The setup link you are trying to access does not exist or has expired.Shown under the title Setup Not Found. Ask the person who sent the link for a new one

SCIM errors

Metorial answers a failed SCIM request with status 400 and puts the message in the detail field. The directory's logs in Metorial show each request with its body and response.

detailCause and fix
SCIM group display name is requiredThe identity provider pushed a group without a name. Set the group's display name and push it again
Every SCIM group member must have a valueA group update listed a member without an ID. Fix the attribute mapping for group members in the provisioning settings
SCIM group references unknown users:The group lists members Metorial has not received as users. Their IDs follow the colon. Provision the users first, then push the group again

If users are not created at all, open the directory's logs. No entries means the identity provider is not calling Metorial, so compare the SCIM endpoint and Bearer token it uses with the directory's values.

Next steps